Figure 20. Experiment setup for Case 1 free jet flow separation at vertical edge
The prototype case, and scaled models of the prototype having distortions
ratios (NX /NZ ) equal to 2, 4, and 6, were tested for three different flow rates
(Q = 1.5 L/sec, 1.0 L/sec, and 0.75 L/sec). This gave a total of 12 experiments,
as detailed in Table 5. The elevation of the LDV measurement volume above
the bottom, and the horizontal measurement grid spacing (∆x, ∆y) for each
experiment are listed in Table 6.
42
Chapter 5 Turbulence Scale Effects Experiments